After specifying your file(s), a progress dialog bar will be displayed as CSBatch works its way through your data file, then Text Viewer is launched and generate the following listing report:
The "CSPro Process Summary" gives you information about the records and cases. In this example:
• 29143 records were read from the input file, which represent 100 % of the input file
• "Ignored" is the sum of "Unknown" and "Erased" cases.
• "Unknown" represents number of cases with invalid record type code.
• "Erased" represents number of records with a "~" character
• The list report contains 47063 messages of which: 36 messages were defined by the user; 9004 are warning messages generated by the system; and 38023 are error messages generated by the system
• "Level 1" indicates that the following statistics are for Level 1 only. If the application had more than one level, the statistics will be displayed for each level.
• The input data file included 4872 cases (questionnaires) of which: there were "0" case with bad structure, meaning that no required records were missing; and 4872 cases were written to the output file ("Level Post").
The "Process Messages" gives you information on each case:
• *** Case (010705802820460191) has 12 messages (8 E/ 2 W/ 2 U)
Indicates that questionnaire 010705802820460191 (codes correspond to the ID items in the Dictionary) has 12 messages: 8 error messages generated by the system; 2 warning messages generated by the system; and 2 error messages defined by the user.
• W 88870 Value '01' out of range – check P16_IND(1)
Indicates that field P16_IND in first person (1) has a value "01" which is out of range because it has not been declared in the Dictionary. This is Warning 88870, generated by the system.
• U -69 Household tenure is vacant, but there are 5 person records.
Message defined by the user in line 69 of the program
• E 88212 … H07_RENT should be blank (currently '000')
Indicates that field H07_RENT has a value '000' but it should be blank. (This is a vacant unit)
This is Error 88212, generated by the system.
If a write (.wrt) or frequency (.frq) file was generated, then they will also be loaded into Text Viewer for display; to rotate between the various files, select the "Window" option from Text Viewer, and choose from among the files listed at the bottom. If Text Viewer was already running when you launched your application, it will be refreshed with the latest run results.
See the explanation given under Run an Application